The Sartorius Maxxis 5 freely programmable process controller, designed for applications as diverse as Phase, Batching, Filling, IBC, Counting and Truck Weighing. Extensive connectivity options and co

详细介绍

Maxxis 5过程控制器

 

概述

The Sartorius Maxxis 5 freely programmable process controller, designed for applications as diverse as Phase, Batching, Filling, IBC, Counting and Truck Weighing. Extensive connectivity options and compatibility with all analogue load cells and the digital Pendeo® load cells as well as platform scales and many more weighing solutions. Maxxis 5

 

特性

  1. Process Controller for the automated control of weighing processes with up to four scales
  2. Wide range of opportunities for flexible integration such as option cards, housings, W&M certification and EX approvals
  3. DAT, multilingual easy-operation interface, backup function, service reports, simulation
  4. BASIC application with weighing, check and remote terminal function
  5. With an additional license: internal alibi memory, OPC server, tilt correction
  6. Supplied with Ethernet TCP | IP, Modbus TCP, RS232, RS485, USB, SD Card

 

参数

Load cell connection

All strain gauge load cells;

6- or 4-wire connection

Load cell supply

12V, short-circuit proof.

External load cell supply possible.

Minimum load impedance

min. 75 Ohm

e.g. 6 load cells with 650 Ohm

or 4 load cells with 350 Ohm

Measuring principle

Measuring amplifier:

Delta-Sigma converter

Measuring time:

min 5 ms – max. 1600 ms

Digital filter for load cell

4th order (low pass), Bessel, Aperiodic

or Butterworth

ATEX Zone 2/22 approved (Option)

Zone 2, IIC T4 /

Zone 22, IIIC T80°C

Ta: -10°C ... +40°C

Approved for FM/CSA Class I Div.2

(Option)

NI / I / 2 / ABCD / T4

Ta = -10°C to +40°C – 2015571; NIFW

ANI / I, II, III / 2 / ABCD / T4

Ta = -10°C to +40°C – 2015571; NIFW

A | D Converter Input range

4,8 nV (appr. 7.5 Mio. div.)

Usable resolution: 0.2 μV/d

Measuring signal: 0 to 36mV

(for * nominal load)

Linearity

< 0,003%

Control outputs

4 relay two way contact

Max. switching voltage 31 V DC | 24 V AC

Max. switching current: 1 A

Control Inputs

Quantity: 4 opto-decoupled inputs

Can be used as 'passive' or 'active'

Voltage

Input (active):

Can be switched via a potential-free contact

Input (passive):

– Logic 0: 0 to 5 V DC or

– open Logic 1: 10 to 28 V DC

External power supply required

Current: <7 mA @ 24 V

<3 mA @ 12 V

Power Supply

100 – 240 VAC, (+10/-15 %), 50 - 60 Hz max.

21 W/44 VA

Optional:

24 VDC, (+/-10 %), max 20 W

Temperature effects

Zero: TK0 m < 0.05 μV/K RTI

Span: TKspan < +/- 4 ppm/K

Environmental conditions

Temperature

W&M: –10 °C to +40 °C

Operation: –10 °C to +50 °C

Storage: –20 °C to +70 °C

Weight

Net: 3 kg

Shipping weight: approx. 4 kg

 

订货型号

Type Description Order Number

Maxxis 5 Process Controller, incl. Ethernet TCP | IP and Modbus TCP

1 × RS232 and 1 × 485 | 422, 1 × USB, 1 × SD Card,

4 × digital input (active or passive optional) and 4 × digital outputs as relay

9405 159 00000

 

相关型号

Maxxis 4

PR 5900/00 Maxxis 5 Process Controller with options: Panel housing (G1), A | D converter(W1), 110 | 230 V (L0),

BASIC Application (H0), Digital Input passive (DE1)

9405 159 00001

PR 5900/01 Maxxis 5 Process Controller with options: Panel housing (G1), A | D converter(W1), 24 V (L8),

BASIC Application (H0), Digital Input passive (DE1)

9405 159 00011

PR 5900/02 Maxxis 5 Process Controller with options: Table top housing (G2), Rear plate cable glands (L12),

A | D converter (W1), 110 | 230 V (L0), BASIC Application (H0), Digital Input passive (DE1),

Power cable with Euro Plug (EU)

9405 159 00021

PR 5900/03 Maxxis 5 Process Controller with options: Housing with bracket (G3), Rear plate cable glands (L12),

A | D converter(W1), 110 | 230 V (L0), BASIC Application (H0), Digital Input passive (DE1),